Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 165(1-4): 162-5, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25897144

RESUMEN

The objective of this work was to evaluate the air kerma-area product (PKA) and the skin absorbed dose in the region of the eyes, salivary glands and thyroid of the patient from mandible examinations performed with three cone-beam computed tomography (CBCT) scanners, i.e. i-CAT classic, Gendex CB-500 and PreXion 3D. For the dosimetric evaluation, an anthropomorphic head phantom (model RS-250) was used to simulate an adult patient. The CBCT examinations were performed using standard and high-resolution protocols for mandible acquisitions for adult patients. During the phantom's exposure, the PKA was measured using an ionising chamber and the absorbed doses to the skin in the region of the eyes, thyroid and salivary glands were estimated using thermoluminescence dosemeters (TLDs) positioned on the phantom's surface. The PKA values estimated with the CBCT scanners varied from 26 to 138 µGy m(2). Skin absorbed doses in the region of the eyes varied from 0.07 to 0.34 mGy; at the parotid glands, from 1.31 to 5.93 mGy; at the submandibular glands, from 1.41 to 6.86 mGy; and at the thyroid, from 0.18 to 2.45 mGy. PKA and absorbed doses showed the highest values for the PreXion 3D scanner due to the use of the continuous exposure mode and a high current-time product.


Asunto(s)
Tomografía Computarizada de Haz Cónico/normas , Mandíbula/diagnóstico por imagen , Dosis de Radiación , Radiometría/normas , Aire , Antropometría , Tomografía Computarizada de Haz Cónico/métodos , Diseño de Equipo , Ojo/efectos de la radiación , Cabeza/efectos de la radiación , Humanos , Imagenología Tridimensional/métodos , Glándula Parótida/diagnóstico por imagen , Fantasmas de Imagen , Piel/efectos de la radiación , Glándula Submandibular/diagnóstico por imagen , Dosimetría Termoluminiscente/métodos , Glándula Tiroides/diagnóstico por imagen , Tomógrafos Computarizados por Rayos X
2.
Radiat Prot Dosimetry ; 158(2): 175-80, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24043877

RESUMEN

The aim of this work was to perform a dosimetric evaluation of two cone-beam computed tomography scanners. The study was performed with two scanners: i-CAT classic and PreXion 3D. Air kerma-area product (PKA) was measured for all full-arch dental implant planning protocols. Surface air kerma was also estimated at the region of the eyes, salivary glands and thyroid using thermoluminescence dosemeters positioned on an anthropomorphic phantom. The PKA values for the i-CAT classic ranged from 24 to 180 µGy m(2) and, for the PreXion, from 70 to 138 µGy m(2). The large variation of these values was mainly caused by acquisition time and field of views. The surface air kerma values were from 0.08 to 3.39 mGy at the eyes, 0.50 to 3.96 mGy at the parotids, 0.11 to 2.95 mGy at the submandibular glands and 0.05 to 1.32 mGy at the thyroid. These values are comparable with those found in the literature.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Implantes Dentales , Radiometría/métodos , Aire , Algoritmos , Antropometría , Brasil , Calibración , Diseño de Equipo , Humanos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Dosimetría Termoluminiscente , Tomógrafos Computarizados por Rayos X
3.
Radiat Prot Dosimetry ; 148(4): 452-6, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21561947

RESUMEN

The aim of this study was to evaluate the image quality of 29 computed tomography (CT) scanners in Brazil and to perform estimations of patient dose and image quality of common CT examinations at these equipment. The volume CT air kerma indexes (C(VOL)) were estimated, using normalised weighted air kerma indexes, supplied by the ImPACT group. The image quality tests were performed using the phantom and accreditation protocol from the American College of Radiology (ACR). The C(VOL) values for head scans varied between 8.7 and 108 mGy. The Hi-res chest examinations presented C(VOL) values varying from 0.4 to 32 mGy. For abdominal scans, the estimated C(VOL) values varied between 4.1 and 94 mGy. This wide variation of air kerma between different centres is related to the scanner type and also to the scanning parameters. The results also showed that the image quality did not attend all ACR CT accreditation requirements.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Radiometría/instrumentación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/efectos de la radiación , Aire , Brasil , Diseño de Equipo , Humanos , Fantasmas de Imagen , Radiología/métodos , Tomógrafos Computarizados por Rayos X , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...